Skip to Main Content
Data services feedback portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about CONNECT products and services. All of the feedback you share here is monitored and reviewed by the CONNECT product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT data services. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 650

Access Adapter configuration via cloud (read files from edge)

Browse device(s) view/update configuration for a device verify configuration naming updates - typo, change to naming customize for site specific scenario Push updated configuration
Glenn Moffett 9 months ago in Software Management / Edge Management Integration 0 No status

SDS Explorer - Customize Columns

I would like to be able to add custom columns by specifying a metadata key. This is especially important in Communities. Since we do not have the benefit of Assets in Communities, Stream meta data can be used make associations and to search and fi...
John Marriott 4 months ago in Data Management & Storage / SDS Explorer 0 No status

PI Adapter for GE e-terrahabitat/HabConnect

We need a new robust product to support data transfer between GE e-terrahabitat/HabConnect and PI. This product would need to support the following: Highly available remote management/deployment multiple instances on a single node (to support larg...
Guest almost 2 years ago in AVEVA™ Adapters / New Connectivity 0 No status

Ban Russian industries using PI

Call for AEVA to exit Russian market immediately of obvious reasons, cancel product license and prevent existing users from accessing application. It is confirmed that PI still actively used on Yamal LNG, Arctic LNG2, Sakhalin LNG sites.
Guest 9 months ago in CONNECT to PI 0 No status

API to check Adapter buffer statistics

We can check buffer statistics with PI Buffer subsystem (pibufss -cfg, qs) and also with PI Connector/Relay, to verify whether Buffer is healthy, events in queue and etc.Adapter does not has any API to check this.
Guest over 1 year ago in AVEVA™ Adapters / General 0 No status

Monitoring network traffic of PI to CONNECT Agent

If there is a connection between a PI Server and a restricted Network (limited traffic due to a restriction of the data plan or restrictions by government authorities - e.g. China), it would be helpful to have information about the actual and esti...
Hans-Otto Weinhold over 2 years ago in PI to CONNECT / General 0 No status

Add parameter "Max Monitored Items per Subscription"

The connector for OPC UA includes a parameter “Max Monitored Items per Subscription”, which is very helpful in managing UA servers which may have limits on the maximum items per subscription. This parameter needs to also be available in the adapters.
Guest 5 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 3 Future consideration

PI Adapter for OPC UA should send the previous value when it has been with the same value for a long time

"This enhancement request proposes a solution to address the issue of data interpolation between two values far apart in time in adapter data collection. The suggestion is to include the value right before the new data point, ensuring the fidelity...
Fabio Dani almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Improve the message for performing on demand History Recovery on datacollectionmode: "CurrentWithBackfill" and "CurrentOnly"

Running edgecmd to perform HR on demand on the datasource: datacollectionmode of Non HistoryOnly. will return the following error: Operation Failed: NotFound (404)Unexpected error: Unexpected character encountered while parsing value: 0. path '", ...
Guest 10 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Add database filter on AFAnalysisService.QueryRuntimeInformation

Hello, Could it be possible to add a dedicated filter on dataabse for the method AFAnalysisService.QueryRuntimeInformation? Indeed, on large systems, the PI Analysis service timeout because the call is not enough efficient. In fact, the only way t...