Skip to Main Content
Data services feedback portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about CONNECT products and services. All of the feedback you share here is monitored and reviewed by the CONNECT product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT data services. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 204 of 694

read files from AWS S3, Azure storage and Google Cloud Storage

For example, model inference data is written to storage and required destination is a PI System.
Guest about 3 years ago in AVEVA™ Adapters / New Connectivity 0 No status

AF Attribute not recongized in CONNECT transfer configuration if PI point data reference config string contains a datatype

We encountered an issue with PI to CONNECT (using current version of the Agent 2.2) not recognizing AF Attributes with PI Point Data References which have the pointtype in the data reference configuration. So that means if there is a config string...
Guest about 2 years ago in PI to CONNECT / General 0 No status

Better support of IP21 OPC UA Server with PI Adapter for OPC UA

We have been using the PI Adapter for OPC UA in its current version to collect data from IP21 OPC UA Server during a lighthouse project. However, the configuration was a bit cumbersome since the OPC UA Server of AspenTech uses an opaque mechanism ...
Hans-Otto Weinhold over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Make a BACnet/SC adapter

BACnet/SC is essentially the same as BACnet/IP... but secures the communication
Guest over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for BACnet 1 No status

Allow multiple references to holding register for bit extraction

Given a 16bit integer holding register, in certain instances we only care for specific bits rather the integer value. Using the bitmap allows the selection of those specific bits but you can only reference the register once. i.e. In data selection...
Guest over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 8 Future consideration

AVEVA Adapter for WITSML

We need an Adapter for WITSML to get data from drilling, completions, and interventions of oil wells to CONNECT data services, so the data can be shared between multiple stakeholders.
John Marriott over 1 year ago in AVEVA™ Adapters / New Connectivity 0 No status

Use PI Server Alternate Display Name in stream naming pattern

The PI Server Alternate Display Name is only used to build the stream IDs. It would be better to use it in the stream naming pattern as well.
Clement Dekeyser almost 3 years ago in PI to CONNECT / General 0 No status

Seamless change of PI Server Alternate Display Name

When the PI Server Alternate Display Name is modified, new streams are created to receive live data while historical data remains only in the existing streams. It would be better to automate: the deletion of existing streams the backfilling of new...
Clement Dekeyser almost 3 years ago in PI to CONNECT / General 0 No status

CONNECT Agent for AVEVA Plant SCADA (Citect)

AVEVA Plant SCADA 2020r2 and newer, has an OPC UA Server, so the AVEVA Adaptor for OPC UA can be used to send data to CONNECT data services (AVEVA Data Hub). However native connectivity like the PI-to-CONNECT Agent or the System Platform Connector...
John Marriott over 1 year ago in AVEVA™ Adapters / New Connectivity 0 No status

More options when searching for PI Points

During a Lighthouse project a customer noted that they have a number of points in their data archive that are no longer on scan. It would be helpful, then, if the PI Point Search facilities in PI to CONNECT allowed use of the ‘scan on/off’ flag so...
Guest about 3 years ago in PI to CONNECT / General 0 No status