To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Better support of IP21 OPC UA Server with PI Adapter for OPC UA

We have been using the PI Adapter for OPC UA in its current version to collect data from IP21 OPC UA Server during a lighthouse project. However, the configuration was a bit cumbersome since the OPC UA Server of AspenTech uses an opaque mechanism ...
Hans-Otto Weinhold about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

PI Adapter for Structured Files - User friendly interface

Make the configuration experience more user friendly. Add a user interface for adapter configuration and management.Today, this adapter is too configuration intensive
Rene Thomassen about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for Structured Data Files 1 No status

Allow multiple references to holding register for bit extraction

Given a 16bit integer holding register, in certain instances we only care for specific bits rather the integer value. Using the bitmap allows the selection of those specific bits but you can only reference the register once. i.e. In data selection...
Guest over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 8 Future consideration

Calc Scheduling: Wait for Data

The ability to say wait until I have all the data for my calculation inputs for situations where the data comes in more slowly. I need more flexibility in the scheduling of calcs.
Guest about 4 years ago in General / Calculations 0 No status

Asset Status Aggregations

Ability to aggregate the status of measurement condition evaluation groups below an Asset into a single Asset Status. Ability to aggregate the status of multiple Assets into higher level organizations such as 'Factory'/Building, Site, Customer, ...
Guest about 4 years ago in General / Calculations 0 No status

OCS Integration with Matlab

Ability to have a pluglin that allows matlab to get data sourced from OCS.
Guest about 4 years ago in Data Platform Integration / New Integrations 0 No status

Seeq Integration with AVEVA Data Hub

Provide an integration between Seeq & AVEVA Data Hub
Guest about 4 years ago in Data Platform Integration / New Integrations 0 No status

AVEVA Adapter for WITSML

We need an Adapter for WITSML to get data from drilling, completions, and interventions of oil wells to CONNECT data services, so the data can be shared between multiple stakeholders.
John Marriott about 2 years ago in AVEVA™ Adapters / New Connectivity 0 No status

Allow the BACnet Adapter to handle responses with an LVT that does not match the request

Currently the BACnet Adapter expects devices to respond with the same "Length Value, and Type" (LVT) value as the request. When this occurs the BACnet Adapter cannot parse the data in the response. For example: Request from Adapter, LVT=1 Response...
Guest over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for BACnet 0 No status

Addition of substitution parameters in DefaultStreamIdPattern -> specify a ValueField for it to read from

People wanting to use a single EventHub and Container holding events from many sources with common attribute naming. Want to be able to differentiate the naming of the pi tags based on source. Being able to substitute a unique source identifier (s...
Guest over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Azure Event Hubs 0 No status