To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT data services. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Ideas

Showing 118 of 703

Support POST/PUT/DELETE requests to allow adding/editing new Edge System Types

Allow customers to send POST/PUT/DELETE requests to the SoftwareManagement/Types endpoint so they can create/modify/remove their own custom Edge System Type Currently only GET requests are supported and customers can only use the existing Edge Sys...
Jason Lu 5 months ago in Software Management / Edge Management Integration 1 No status

PI Adapter for OPC UA should poll a series of items based on a trigger events

Same as the PI Interface for OPC DA feature with "Trigger Tags", the idea is to poll for updates on a series of item streams (tags) only when a certain item stream updates. The benefit of this is to create timestamp alignments between a series of...
Guest over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

PI to Connect Agent instance Failover

on behalf of customer: We would like to see agent failover added to PI to Connect. The PI System already provides high availability, and extending this capability into PI to Connect would deliver a resilient hybrid infrastructure end-to-end. Histo...
omar alomari 4 months ago in PI to CONNECT / General 1 No status

Pi adapter OPCua able to rename pi-tags

As per title
Guest 3 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 3 Tell us more

Error handling for OPC UA Server nodes with "Null" data type

Using a combination of Honeywell Experion OPC UA and the Aveva OPC UA Adapter, we have observed that when an instrument physically fails in the field or goes offline / stops sending communication to the Experion server, it may appear in the Honeyw...
ChrisMcKee 3 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

OPC UA Adapter Create Tag on Discovery

For the OPC UA Adapter, we are noticing that a tag won't be created until a data point comes in after the tag is added to the data filter. That causes issues for slow updating tags. For instance an open/shut valve that is rarely operated. We have ...
Guest 8 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Future consideration

Add an option to disable endpoint validation between results of GetEndpoints and CreateSession

As discussed in OPC UA Adapter - Mismatch of Endpoints returned by GetEndpoints and CreateSession , in the OPC UA SDK 4.1.0+ endpoint validation was added to compare results returned in responses to GetEndpoints and CreateSession requests. The OPC...
Guest 9 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Planned

Allow Multiple Data Archives per PI to CONNECT Agent

Allowing data transfer for tags from multiple PI Data Archives with one agent will help to cut down on the number of agent services, and therefore machines, that need to be involved to send data from PI to CONNECT.
Guest over 3 years ago in PI to CONNECT 0 In development

PI to CONNECT should have a verification tool to make sure there are no gaps in the data

When using PI to CONNECT there might be errors in the transfer due to disconnections or other network issues. Ideally PI to CONNECT would have a tool to verify if the data was properly transferred by checking the data.
Fabio Dani 8 months ago in PI to CONNECT / General 0 No status

Root Element should be added to the transfer

When we create a transfer from PI AF there is a way to select a Root Element to start the search. However the root element from where we start the search is not added to the transfer. Ideally we would be able to add the root element into the trans...
Fabio Dani 3 months ago in PI to CONNECT / General 0 No status