To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT data services. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 121 of 694

Provide alternative message to 'No value defined"

When querying AF Element Information certain values display: "No value defined." and customer reaction was that there was something not working correctly/error that needed to be investigated. Suggestion was to change text to either show the value ...
Glenn Moffett almost 2 years ago in PI to CONNECT / General 0 No status

Simplify the security configuration for OPC UA

The newer OPC UA protocols have stricter security standards, which is good, but that makes configuring connections more difficult, especially with regard to the need to put in tunneling and open ports. It should be easier to establish a secure con...
Guest 12 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

API Console request-timeout and paging support

Provide option to modify request-timeout setting and optionally return multiple pages to aid in querying datasets and learning about the API
Glenn Moffett almost 3 years ago in Developer Resources / AVEVA™ Data Hub Developer Tools 0 No status

For PI substitution events, update the stream property IsSubstituted

Scenario: PI event substitutions for the preceding two months must be supplied to a data warehouse for reporting purposes. Updating IsSubstituted stream property, would allow an application to query for stream events where values had been substitu...
Glenn Moffett almost 3 years ago in PI to CONNECT / General 0 Evaluating

Documentation of EDS Modbus TCP Adapter needs to be updated on removed 32-bit register support for Modbus TCP Adapter

Challenge: The current version of PI Adapter for Modbus TCP does not any longer support 32-bit Holding/Input registers as this is outside of the Modbus specifications. However, in some cases, 32-bit register values have to be read from 16-bit regi...
Hans-Otto Weinhold about 2 years ago in AVEVA™ Edge Data Store / Ingress 0 Planned

EDS: Modbus Serial Connector

Ability for Modbus Serial connector to write data to Edge Data Store.
Guest about 3 years ago in AVEVA™ Edge Data Store / Ingress 1 Declined

The ability to share the current API Console URI as an encoded URL, just like sharing a trend

The ability share trends as encoded URLs is incredibly useful. Another area where exploration and collaboration can be done is in the API Console, and there I'd love the ability to craft a query URI and then be able to save that query with a sing...
Guest about 3 years ago in Developer Resources / AVEVA™ Data Hub Developer Tools 0 No status

AF Attribute not recongized in CONNECT transfer configuration if PI point data reference config string contains a datatype

We encountered an issue with PI to CONNECT (using current version of the Agent 2.2) not recognizing AF Attributes with PI Point Data References which have the pointtype in the data reference configuration. So that means if there is a config string...
Guest about 2 years ago in PI to CONNECT / General 0 No status

Better support of IP21 OPC UA Server with PI Adapter for OPC UA

We have been using the PI Adapter for OPC UA in its current version to collect data from IP21 OPC UA Server during a lighthouse project. However, the configuration was a bit cumbersome since the OPC UA Server of AspenTech uses an opaque mechanism ...
Hans-Otto Weinhold over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Use PI Server Alternate Display Name in stream naming pattern

The PI Server Alternate Display Name is only used to build the stream IDs. It would be better to use it in the stream naming pattern as well.
Clement Dekeyser almost 3 years ago in PI to CONNECT / General 0 No status