To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT data services. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 89 of 694

Please add a feature for the OPC UA adapter to enable the adapter to only store values with a good status or rather filtering out bad values

When receiving bad values from the OPC UA Server to the adapter there is no option to filter out bad values. So these values get stored in the Data Archive and are causing problems with analyses (e.g. expression or Event Frame generation). At the ...
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Edge Data Store Calculations

Enable customers to create real-time calculations on EDS data.
Guest about 3 years ago in AVEVA™ Edge Data Store / Analytics & Calculations 3 Evaluating

Ability to set a "Rolling forward" date and time interval for the Power BI Connector

When the Power BI Connector gets data every XX minutes (30 minutes for ExxonMobil) for a period of time (2 years) from CONNECT DataViews, it adds millions of data points every XX (30) minutes. As such, it needs to move the START time of the query ...
Hege Dammen 5 months ago in Data Platform Integration / Power BI Connector 0 No status

Edge Data Store Visualization

Ability to have basic visualization of data from the Edge Data Store for local operations.
Guest about 3 years ago in AVEVA™ Edge Data Store / Visualization 2 Evaluating

remote ingress to EDS

Enable remote access to EDS OMF endpoint to support deployments where Adapter/OMF application is installed on different host/network to EDS because architecture must fit in with tiered networks for critical asset security. For example remote sites...
Guest about 3 years ago in AVEVA™ Edge Data Store / Ingress 3 Future consideration

Adapter for OPC UA to support Global Discovery Server

Currently, to manage the OPC UA Server/Adapter certificate, we have to manually move the certificate or get the certificate trusted beforehand. This is expected for self signed Application certificate for both the Server and the Client (Adapter). ...
Guest 4 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 2 Tell us more

PI Adapter for OPC UA should preiodically retry to subscribe to each node for which subscription failed at startup

Currently the PI Adapter for OPC UA tries to subscribe to all the OPC UA nodes configured in the Data Selection configuration at startup. However, when as issue occurs during the subscription to an OPC UA node, that node will not be included in da...
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Ua Server force failover / improve failover logic

Let me preface this by saying that I know it is a workaround for a non-compliance with the OPC UA specifications. The point is that the situation described below is unfortunately all too common and the workaround is needed. It often happens that t...
Guest over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

PI Adapter for OPC UA data conversion

As a PI System Administrator, I would like to be able to apply conversion factors to the data that is being gathered from our OPC UA server. This would allow us to get data in the format/units we'd like, without requiring extra tags and/or calcula...
Guest about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 2 No status

Prevent PI Adapter for OPC UA from modifying/override stream overrides and metadata upon restart

Problem: I have configured PI Adapter for OPC UA to collect data from an OPC UA Server. Since UoMs are not assigned properly, I created stream overrides in AVEVA Data Hub to assign the proper UoM to the particular stream. I also associated stream ...
Hans-Otto Weinhold over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 4 In development