We created this site to hear your enhancement ideas, suggestions and feedback about CONNECT products and services. All of the feedback you share here is monitored and reviewed by the CONNECT product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT data services. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 79 of 693

The ability to define the number of decimal points for each parameter in the DataView column.

Most Values in a Dataview column (streams) will have a limited number of decimals both when viewed, calculated or measured. Very few Values on ANY type of measurement or calculation will have an accuracy of more than 6 decimals but often 1-2 decim...
Hege Dammen 5 months ago in Data Views / General 0 No status

Use stream NAME instead of stream ID for the API call

Today hundreds of Users do simple queries to get multiple PI tags many times per day in their existing Cloud platform. Using the API call on CONNECT the users do not know the steam ID of a tag they only know the TAG NAME. As such, it is a signific...
Hege Dammen 5 months ago in Data Views / General 0 No status

Expose count parameter to dataviews requests

By default, dataviews will return pages of 25k rows at a time, but allow you to manually specify up to 250k rows per page. For large data ingests, this default value can result in longer data loads because many "smaller" pages are being loaded. Gi...
Adam Fink 5 months ago in Data Platform Integration / Power BI Connector 0 No status

displayname/localname for identifier that excludes namespace and data type

Example: OPC UA Server 'Name': 2.0:W-HVAC-AC-1-IO!Wtot Namespace: 2 Datatype: 0 Identifier: W-HVAC-AC-1-IO!Wtot OPC UA Server 'DisplayName': W-HVAC-AC-1-IO!Wtot OPC UA Adapter {Identifier} returns: 2.0:W-HVAC-AC-1-IO!Wtot Required stream name: W-H...
Glenn Moffett over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Enable Adapter for OPC UA to use the Pub/Sub method

Pub/Sub is proposed to be a more efficient and scalable method of transferring data using OPC UA. Allowing the adapter to access data in this way would increase the options for data collection, and allow the OPC UA adapter to be used in many more ...
Mike Horrocks over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Want ability to get simple average across multiple streams in a data view

With the data view currently I can get an average across the values in one stream by retrieving the calculated summary. I want to be able to get the average across multiple streams in the data view.
Cynthia Bourne over 1 year ago in Data Views / General 0 No status

Filter Data in a Data View

Ability to filter data coming back in a Data View. For example, grab all data when the RPM > 9000.
Guest about 3 years ago in Data Views 0 No status

PI Interface DNP3 - unsolicited data listen only mode of operation requested

Is there an option in DNP3 driver (In fact at TCP level) to make it listen on a certain (usually 20000 for DNP3)? In era of IoT devices, most devices are sleeping devices, they wake up usually once a day and push data to DNP3 Master (PI), however ...
Guest about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for DNP3 1 Tell us more

PI Adapter for OPC UA should send the previous value when it has been with the same value for a long time

"This enhancement request proposes a solution to address the issue of data interpolation between two values far apart in time in adapter data collection. The suggestion is to include the value right before the new data point, ensuring the fidelity...
Fabio Dani over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Failover support for Adapter for DNP3

This is a new idea for the failover functionality specific to the Adapter for DNP3. Copied from the original idea (https://pisystem.feedback.aveva.com/ideas/PIADAPTERS-I-23): As a customer, I need to ensure that the primary instance of the adapter...
Jiyeon Hwang over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for DNP3 0 Planned