Skip to Main Content
Data services feedback portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about CONNECT products and services. All of the feedback you share here is monitored and reviewed by the CONNECT product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT data services. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 58 of 694

Expand Healthpoint (Device Status) Information of the PI Adapter for Modbus TCP from Component to "Device" Level

When configuring PI Modbus TCP adapter you first define a component level and under this type you define your different devices/machines/sensors. In case of a broken connection to one of the devices the healthpoints currently only deliver the stat...
Guest almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Support for "RTU over TCP" for Modbus Adapter using MBAP header

Challenge: Today, the PI Adapter for Modbus TCP does not natively support " RTU over TCP". It does support Modbus TCP, so as long as the "bridge" properly converts Modbus RTU to Modbus TCP (including the MBAP header), it should work fine. If the b...
Hans-Otto Weinhold about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Time based summary calculations

Ability to perform hourly, daily, weekly monthly, quarterly aggregation summary calculations on data. Often useful for utility consumption KPIs / metrics.
Guest about 3 years ago in General / Calculations 1 No status

Event-based total (non-weighted Total) Summary Type

As a Data View creator, I want an event based total Summary Type data field so that I can see a calculated sum of values that is not weighted by time (or any index)
Guest about 3 years ago in Data Views 0 No status

Add an Aligned data retrieval mode for data views

It would be beneficial to have a data retrieval mode that creates one row per recorded value for one property, and interpolates values at those timestamps for the rest of the properties. This is a hybrid of interpolated and stored, where a single ...
Guest about 3 years ago in Data Views 0 No status

Performance Equation capability in Data Hub

When AVEVA products such as AVEVA Production Accounting use the performance equation capabilities of on-premise PI Server extensively, but when the same product tries to consume the data from the Data Hub for similar complex calculations or valida...
Jaibabu Yakkala over 2 years ago in General / Calculations 0 No status

Make a BACnet/SC adapter

BACnet/SC is essentially the same as BACnet/IP... but secures the communication
Guest over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for BACnet 1 No status

Allow multiple references to holding register for bit extraction

Given a 16bit integer holding register, in certain instances we only care for specific bits rather the integer value. Using the bitmap allows the selection of those specific bits but you can only reference the register once. i.e. In data selection...
Guest over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 8 Future consideration

Reference Manual in Python Client: adh_sample_library_preview

Currently, adh_sample_library_preview is only avaiable in Github Example code. https://github.com/AVEVA/sample-adh-data_views-python/blob/main/program.py However, it is not helpuful for users. It is better to setup "Reference Manual" of adh_sample...
Satoru Arakawa over 1 year ago in General / Help / Documentation / Videos 0 No status

Calc Scheduling: Wait for Data

The ability to say wait until I have all the data for my calculation inputs for situations where the data comes in more slowly. I need more flexibility in the scheduling of calcs.
Guest about 3 years ago in General / Calculations 0 No status