Skip to Main Content
Data services feedback portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about CONNECT products and services. All of the feedback you share here is monitored and reviewed by the CONNECT product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT data services. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 84 of 693

Add support for monthly, yearly, or other irregular interval Data View queries

I am using Data Views to produce reports containing data queried with a Monthly or Yearly interval. Currently, I have to make a separate query for each month or year and then append the results together as the query intervals are not constant (ex:...
Guest about 3 years ago in Data Views 0 No status

Data Retention configuration for EDS SDS

We have no information regarding data retention. This could be clarified. Data retention should be better configurable as of now, only the stream size can be configured just by estimation. Provide a sizing and calculation tool for Edge Data Store ...
Hans-Otto Weinhold over 1 year ago in AVEVA™ Edge Data Store / Historian 0 No status

Documentation of EDS Modbus TCP Adapter needs to be updated on removed 32-bit register support for Modbus TCP Adapter

Challenge: The current version of PI Adapter for Modbus TCP does not any longer support 32-bit Holding/Input registers as this is outside of the Modbus specifications. However, in some cases, 32-bit register values have to be read from 16-bit regi...
Hans-Otto Weinhold about 2 years ago in AVEVA™ Edge Data Store / Ingress 0 Planned

EDS: Modbus Serial Connector

Ability for Modbus Serial connector to write data to Edge Data Store.
Guest about 3 years ago in AVEVA™ Edge Data Store / Ingress 1 Declined

Video Storage

The ability to store video files in OCS and relate the video to process data by timestamp.
Guest about 3 years ago in Data Management & Storage / Sequential Data Store (SDS) 0 No status

Event-based total (non-weighted Total) Summary Type

As a Data View creator, I want an event based total Summary Type data field so that I can see a calculated sum of values that is not weighted by time (or any index)
Guest about 3 years ago in Data Views 0 No status

Add an Aligned data retrieval mode for data views

It would be beneficial to have a data retrieval mode that creates one row per recorded value for one property, and interpolates values at those timestamps for the rest of the properties. This is a hybrid of interpolated and stored, where a single ...
Guest about 3 years ago in Data Views 0 No status

Support of Enumeration mappings for existing Streams which hold status information as Integer values

Problem: Some data sources (like Modbus PLCs or some OPC UA Servers) expose Status/Enumeration Data (On/Off etc) as an integer number rather than the status itself. This number is then stored in AVEVA Data Hub but to be able to interpret and use ...
Jeff Branfield about 2 years ago in Data Management & Storage / Sequential Data Store (SDS) 0 No status

Add cubic meter per day and thousand barrels per day UoMs

Two very common Unified Supply Chain product UoMs are missing in the Sequential Data Store Type UoMs: cubic meter per day (m3/d) thousand barrels per day (kbbl/d) Both of these are Volume Flow Rate UoMs. Please add these.
Patrick Davis about 1 year ago in Data Management & Storage / Sequential Data Store (SDS) 0 No status

Priviledge can assigined to Streams automatically

When Streams are stored into ADH, administrator has to manage priviledge. 100 streams can be managed manually. But how about 10 thousands Stream? When Streams are stored into ADH, system defines priviledge to each Role automatically. It looks same...