To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT data services. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 128 of 693

Make a BACnet/SC adapter

BACnet/SC is essentially the same as BACnet/IP... but secures the communication
Guest over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for BACnet 1 No status

Allow multiple references to holding register for bit extraction

Given a 16bit integer holding register, in certain instances we only care for specific bits rather the integer value. Using the bitmap allows the selection of those specific bits but you can only reference the register once. i.e. In data selection...
Guest over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 8 Future consideration

AVEVA Adapter for WITSML

We need an Adapter for WITSML to get data from drilling, completions, and interventions of oil wells to CONNECT data services, so the data can be shared between multiple stakeholders.
John Marriott over 1 year ago in AVEVA™ Adapters / New Connectivity 0 No status

CONNECT Agent for AVEVA Plant SCADA (Citect)

AVEVA Plant SCADA 2020r2 and newer, has an OPC UA Server, so the AVEVA Adaptor for OPC UA can be used to send data to CONNECT data services (AVEVA Data Hub). However native connectivity like the PI-to-CONNECT Agent or the System Platform Connector...
John Marriott over 1 year ago in AVEVA™ Adapters / New Connectivity 0 No status

Drive Data Sharing from On-Premises Display

Drive data sharing from a shared on premises PI Vision display. For example, selecting to share a display (or set of displays) externally would automatically copy all supporting data to OSIsoft Cloud Services. The display definition and data are...
Guest about 3 years ago in Community Data Sharing / Display Sharing 0 No status

Display Sharing does not give access to raw data

When sharing information with a partner, the ability to share a display and the partner only gets access to the data through that display. They do not get access to the raw data, only through the view that was shared with them.
Guest about 3 years ago in Community Data Sharing / Display Sharing 0 No status

Allow different host names and URLs for PI Web API

Our PI Web API uses a DNS. The certificate we use is only valid for the DNS alias, not the machine host name. So in our system, we have the need to use the host name for some pre-checks, and the DNS URL for other pre-checks. Can you please separat...
Guest about 3 years ago in Developer Resources / PI System Deployment Tests 0 No status

Allow the BACnet Adapter to handle responses with an LVT that does not match the request

Currently the BACnet Adapter expects devices to respond with the same "Length Value, and Type" (LVT) value as the request. When this occurs the BACnet Adapter cannot parse the data in the response. For example: Request from Adapter, LVT=1 Response...
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for BACnet 0 No status

Addition of substitution parameters in DefaultStreamIdPattern -> specify a ValueField for it to read from

People wanting to use a single EventHub and Container holding events from many sources with common attribute naming. Want to be able to differentiate the naming of the pi tags based on source. Being able to substitute a unique source identifier (s...
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for Azure Event Hubs 0 No status

Error message should be generated for the Modbus request time out

After request time out, Modbus adapter should generate an error as time out after specified duration set by user.
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status