Skip to Main Content
Data services feedback portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about CONNECT products and services. All of the feedback you share here is monitored and reviewed by the CONNECT product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT data services. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 141 of 693

View security rights of a role

I would like to be able to understand, view, and modify the security rights of a role from a single display. It would be great to be able to also go a level up and see what rights a client has and trace which role gives them that right.
Derek Endres almost 2 years ago in General / Security 1 No status

Support for "RTU over TCP" for Modbus Adapter using MBAP header

Challenge: Today, the PI Adapter for Modbus TCP does not natively support " RTU over TCP". It does support Modbus TCP, so as long as the "bridge" properly converts Modbus RTU to Modbus TCP (including the MBAP header), it should work fine. If the b...
Hans-Otto Weinhold about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Provide possibility to create stream metadata from table data

Today we are collecting data from our AspenTech IP21 Server thorugh the PI Adapter for OPC UA and the related AspenTech OPC UA Server. This works perfectly fine for analogue data but not for data which is providing us equipment status information ...
Hans-Otto Weinhold about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for RDBMS 0 No status

Provide additional time formatting options for RDBMS Queries

Background: Today we are collecting data from our AspenTech IP21 Server thorugh the PI Adapter for OPC UA and the related AspenTech OPC UA Server. This works perfectly fine for analogue data but not for data which is providing us equipment status ...
Hans-Otto Weinhold about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for RDBMS 1 Tell us more

Apply configuration remotely from AVEVA Data Hub

Remote configuration of Edge system software (Edge Data Store (EDS) and PI Adapters) from AVEVA Data Hub. The ability to apply configuration and make configuration updates remotely from AVEVA Data Hub. Note: This request is specific to applying co...
Ryan McErlean about 3 years ago in Software Management 0 No status

Cascading Security Inheritance Down to Streams and other Objects in a Namespace

If a single namespace is being used to store data from multiple customers or sites, there needs to be a way to propagate security inheritance down to objects (streams, assets, etc.) within the namespace.
Guest about 3 years ago in General / Security 0 No status

Add support for TLS 1.3 to cloud.osisoft.com

Please add support for TLS 1.3 to cloud.osisoft.com so that it loads more quickly and more securely.
Guest about 3 years ago in General / Security 0 No status

OCS APIs should allow requests with an Access Token issued by my Identity Provider

A customer is building a Web application that needs to access both Microsoft APIs (secured using Azure Active Directory) and OCS APIs (secured using OCS Identity Server). In order for the customer to call both sets of APIs from their Web applicati...
Guest about 3 years ago in General / Security 0 No status

Do not use 'unsafe-inline' in the Content Security Policy

OSIsoft Cloud Services has a very secure configuration already, but it has a sloppy blunder: 'unsafe-inline'. Please stop using it. This should make the configuration even more secure and bring the Security Headers score of OSIsoft Cloud Services ...
Guest about 3 years ago in General / Security 0 No status

Enable OCSP stapling on cloud.osisoft.com

OCSP stapling means the web server sending the certificate revocation status with the certificate to the users' browsers, which avoids the need for the browsers to contact the certificate authority to get this information. OCSP stapling will make...
Guest about 3 years ago in General / Security 0 No status