Skip to Main Content
Data services feedback portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about CONNECT products and services. All of the feedback you share here is monitored and reviewed by the CONNECT product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT data services. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 171 of 693

For PI substitution events, update the stream property IsSubstituted

Scenario: PI event substitutions for the preceding two months must be supplied to a data warehouse for reporting purposes. Updating IsSubstituted stream property, would allow an application to query for stream events where values had been substitu...
Glenn Moffett almost 3 years ago in PI to CONNECT / General 0 Evaluating

Provide ability to custom order CONNECT folder list on Home page

The CONNECT folder list on the Home page is horizontally scrollable and each tile takes up a fair amount of space, so only 4-5 tiles can be seen at once. The tiles are ordered alphabetically and a large folder set requires clicking buttons several...
Cynthia Bourne about 1 year ago in General / Account Management 0 No status

Support for "RTU over TCP" for Modbus Adapter using MBAP header

Challenge: Today, the PI Adapter for Modbus TCP does not natively support " RTU over TCP". It does support Modbus TCP, so as long as the "bridge" properly converts Modbus RTU to Modbus TCP (including the MBAP header), it should work fine. If the b...
Hans-Otto Weinhold about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Provide possibility to create stream metadata from table data

Today we are collecting data from our AspenTech IP21 Server thorugh the PI Adapter for OPC UA and the related AspenTech OPC UA Server. This works perfectly fine for analogue data but not for data which is providing us equipment status information ...
Hans-Otto Weinhold about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for RDBMS 0 No status

Provide additional time formatting options for RDBMS Queries

Background: Today we are collecting data from our AspenTech IP21 Server thorugh the PI Adapter for OPC UA and the related AspenTech OPC UA Server. This works perfectly fine for analogue data but not for data which is providing us equipment status ...
Hans-Otto Weinhold about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for RDBMS 1 Tell us more

read files from AWS S3, Azure storage and Google Cloud Storage

For example, model inference data is written to storage and required destination is a PI System.
Guest about 3 years ago in AVEVA™ Adapters / New Connectivity 0 No status

AF Attribute not recongized in CONNECT transfer configuration if PI point data reference config string contains a datatype

We encountered an issue with PI to CONNECT (using current version of the Agent 2.2) not recognizing AF Attributes with PI Point Data References which have the pointtype in the data reference configuration. So that means if there is a config string...
Guest about 2 years ago in PI to CONNECT / General 0 No status

Better support of IP21 OPC UA Server with PI Adapter for OPC UA

We have been using the PI Adapter for OPC UA in its current version to collect data from IP21 OPC UA Server during a lighthouse project. However, the configuration was a bit cumbersome since the OPC UA Server of AspenTech uses an opaque mechanism ...
Hans-Otto Weinhold over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Make a BACnet/SC adapter

BACnet/SC is essentially the same as BACnet/IP... but secures the communication
Guest over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for BACnet 1 No status

Allow multiple references to holding register for bit extraction

Given a 16bit integer holding register, in certain instances we only care for specific bits rather the integer value. Using the bitmap allows the selection of those specific bits but you can only reference the register once. i.e. In data selection...
Guest over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 8 Future consideration