To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT data services. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 8

Custom HTTP header

add functionality so will bepossible to configure the PI Adapter for OPC UA to include a custom HTTP header when authenticating requests to the PI Web API endpoint The request for this feature recently came up in a support case for PPC (Dev CR: CR...
Guest 4 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 Future consideration

GUI Front End for UA Adapter

The OPC UA Adapter is a replacement for the OPC UA Connector and should thus provide similar functionality by providing a GUI.
Jonathan Brutt over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 7 Future consideration

Bitmask Functionality in AVEVA PI OPC UA Adapter

During the migration from the PI OPC DA Interface to the AVEVA PI OPC UA Adapter, we noticed that the ability to apply bitmasks to incoming values is no longer supported. This functionality is critical in many existing implementations, especially ...
Guest 4 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 Future consideration

OPC UA Adapter Create Tag on Discovery

For the OPC UA Adapter, we are noticing that a tag won't be created until a data point comes in after the tag is added to the data filter. That causes issues for slow updating tags. For instance an open/shut valve that is rarely operated. We have ...
Guest 3 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Future consideration

Detect and monitor which OPC UA server the PI Adapter is connected to

When configuring a PI Adapter to leverage server-level redundancy, it is not currently possible to monitor which server instance the PI Adapter is connected to. Surfacing this information would allow server administrators to better monitor the hea...
Giulio Cattarin over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 3 Future consideration

Add parameter "Max Monitored Items per Subscription"

The connector for OPC UA includes a parameter “Max Monitored Items per Subscription”, which is very helpful in managing UA servers which may have limits on the maximum items per subscription. This parameter needs to also be available in the adapters.
Guest 10 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 3 Future consideration

Automatically detect new AF Elements and replicate them to CONNECT

As an AF Administrator, when I add new equipment to our plant and create new elements/attributes in AF to represent that equipment, I want that to be automatically replicated to CONNECT so I don't have to manually update a PI to CONNECT transfer t...
Guest about 3 years ago in PI to CONNECT 2 Future consideration

Automate dataset selection for each PI to CONNECT Agent

We would end up with more than 60+ PI to CONNECT Agents to configure. We have a strong AF hierarchy across our sites and could perfectly prepare a unique AF rootpath to select the relevant dataset to push from PI/AF to CONNECT for each 60+ connect...
Christian Leroux over 2 years ago in PI to CONNECT / General 1 Future consideration