To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT data services. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 19

Allow Definition of Point Attributes via OMF to PI Web API

When creating containers via OMF the PI Points are created with default Point Attributes - if these need to be changed it is a manual process to subsequently change the attributes appropriately. As OMF solutions can be easily deployed it would be ...
Guest about 3 years ago in Developer Resources / Open Message Format (OMF) 2 No status

Design some UI for PI Adaptors

Design some UI for PI Adaptors, so it will be user friendly to configure the data source or data reading configurations etc. It is really hard to configure or troubleshoot an issue in PI Adaptor without Proper UI.
Guest 11 months ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 1 No status

PI Adapter for MQTT should include MQTT broker

Having to deal with a MQTT broker between the data source and the PI Adapter adds a single point of failure to the data handling and weakens the data flow end-to-end. From the data source we can guarantee that the data will reach the MQTT broker, ...
Guest about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

Enable subscribe using wildcard for AVEVA Adapter for MQTT

It would be handy to have the PI Adapter for MQTT to be able to subscribe to a broker by using wildcards only. Right now, we need to specify each individual topics on the data selection rule, and this eventually comes as individual subscription as...
Guest 11 months ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

Allow EdgeCmd to set null or empty string parameter values

As per KB000042993, setting parameters with EdgeCmd that are <null> or "" (empty string) is not possible. Instead the JSON configuration file must be created and used in place. It would be more intuitive if executing commands such as: edgecm...
Mike Horrocks over 1 year ago in AVEVA™ Edge Data Store / General 1 No status

Provide GUI for Configuration

Edge Data Store would require a GUI for configuration and health status to work more efficiently to set it up with too many efforts. The GUI should allow to set up the connection to the Data sources of the included PI Adapters, provide OPC UA brow...
Guest almost 2 years ago in AVEVA™ Edge Data Store / General 0 No status

More control on MQTT parameters on the AVEVA Adapter for MQTT

It would be nice to have more control on additional MQTT parameters for the AVEVA Adapter for MQTT. We are especially interested in having control on the QoS of the subscription. Setting this would give us more control in buffering, especially whe...
Guest 11 months ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

Allow MQTT adapter to parse timestamps in local time without specifying a timezone suffix to each timestamp

We would like the MQTT Adapter to be able to interpret timestamps in local time without needing to explicitly state the timezone or UTC offset in each timestamp, but for the adapter to always interpret the timestamps as being in a specific timezon...
Guest about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

OMF should accept the use of special characters like / : @ ! + % < > ( ) when writing to PI WebAPI OMF endpoint

The OMF 1.1 spec does not allow certain special characters that are indeed accepted in the PI Core system like these here: / : @ ! + % < > ( ) When OMF is used to write to PI Core via the PI WebAPI OMF endpoint, this hinders the migration p...
Guest about 3 years ago in Developer Resources / Open Message Format (OMF) 0 No status

Improve throughput

I am not sure if this is a limitation connected to the OMF, WebAPI, or https itself, but in the manual it is given that the maximum message size is 192KB. I am aware that compression is recommended and applied by default by the adapters. For the r...